Pack Configuration: Configurable up to 16 P
Pack Capacity: Total 115Ah, 78kWh
Usable: 99 Ah 67 kWh
Pack Voltage Operating (min, Max, nom): 460 V, 773 V, 679 V
Discharge Capability (1.5C)3: 117 kW
Normal Charge Capability (0.3C)2: 23 kW
Fast Charge Capability (0.5C)2: 39 kW
Pack dimensions L x W x H: 900mm x 637mm x 715mm
Estimated pack Weight: ~500kg (1100lb)
Pack Configuration: 8(SSIP)
Module Cell Configuration: 552 (23S24P)
Type of Cooling: Liquid 50/50 Water Ethylene Glycol
Coolant Pressure: Operational: 30 PSI | Maximum: 40 PSI | Pressure drop: -3 PSI @ 24 LPM
Operational Temperature Range: Discharge temperature range: -20C to 60C | Charge temperature range: 0 C to 45 C | *Packs allowed to be heated with external power source between -20 C and 0 C
BMS Control: Internal Master / External Master WakeUp Source: CAN
BMS Power: Input supply: 24V/ 12V | Current consumption: Operating - peak (12V/24V) : 3.4A / 1.65 A | Sleep: 70mA
Firmware: Configurable According to specific application
CAN Channel: Vehicle CAN: JI939-7I (internal) / Romeo Power Proprietary (external) 250Kbps / 500 Kbps Diagnostic CAN: Romeo Power Proprietary 500 Kbps | Batter CAN: Romeo Power Proprietary 500Kbps (only for internal)
Voltage: Over voltage Protection, Under Voltage Protection, Cell Balancing Current/Short Current Overcurrent Protection Temperature Over temperature protection, under temperature protection
Communication: Loss of Heartbeat, BMB Communication
Fault Internal Leakage Detection: FloodDetection
Isolation: Isolation Measurement Protection Service Related: Manual Service Disconnect, High Voltage Interlock Loop Check
Since shipping is by freight truck, please check out with will call and we will email to quote and arrange shipping. Unfortunately at this time we are no longer able to ship these internationally.
Please Note: These newer-generation Menara battery modules were sourced directly from the Virgin Hyperloop project and represent the updated post-recall design. They offer improved reliability and engineering refinements over earlier versions. For clarity, these are not the units previously used by Nikola—these are the later, upgraded production models.
Material Safety Data Sheet PDF
MENARA Pack Series PDF
MENARA 80 Interface Control Drawing PDF